Intrauterine Contraceptives
Authors
INTRODUCTION
Intrauterine methods of contraception (IUC) include the copper intrauterine device Cu-IUD and the levonorgestrel releasing intrauterine system LNG-IUS. IUC is considered to be a long acting reversible method of contraception (LARC);1 with licensed duration of use between 3 and 10 years (Tables 1 and 2). There are a number of Cu-IUDs available and they vary in size, shape, copper content and duration of use. Most consist of a plastic frame with copper wire wound around the stem and some may have copper on the arms of the device. The LNG-IUS consists of an elastomere frame with a reservoir on the stem containing levonorgestrel. With both Cu-IUD and LNG-IUS, threads protrude through the cervical canal into the upper vagina to permit easy removal. Once inserted, effectiveness of IUC does not rely on user adherence and so typical failure rates are much higher than the shorter acting methods of contraception such as the progestogen only injectable and the combined oral contraceptive pill that rely on the user to receive injections every 3 months, or taake a daily pill, respectively.2 In addition to routine contraception the Cu-IUD can also be used for emergency or contraception.
Although IUC is the most widely used method of reversible contraception globally, uptake varies throughout the world.3 Worldwide use was estimated to be 14% in 2007, although this rises in some countries with rates as high as 37% in Eastern Asia.3 High income countries such as the UK, however, have much lower rates of use of IUC (6% using a Cu-IUD and 2% using a LNG-IUS in 2008/09).4 Differences in policy, availability of the method, cost, provider beliefs and user perceptions about the method may influence the variations in use.5
DEVICES AVAILABLE AND DURATIONS OF USE
A Cochrane systematic review that compared the efficacy of the different Cu-IUDs6 concluded that T-shaped Cu-IUDs with copper on the transverse arms (banded devices) are the most effective. Cu-IUDs that contain at least 380 mm2 of copper and have the longest duration of action are recommended as they are most effective and reduce the risk of complications associated with reinsertion.7 In the UK these are the Copper T380A®, TT380 slimline® and T-safe 380A®. Clinicians may also choose one device over the other depending on availability within their setting, length of the uterine cavity (Table 1) and width of the inserter.
Table 1 Copper IUDs available in the UK (adapted from Lader D. Contraception and sexual health 2008/9. A report on research using the ONS Omnibus survey produced by the office for National Statistics, 2009 available at www.statistics.gov.uk4)
Device | Duration of use (years) | Surface area copper (mm2) | Device type | Diameter insertion tube (mm) | Length (mm) | Utero -cervical length (cm) |
10 | 380 | banded | 4.75 | 36 | 6.5–9 | |
TT380 Slimline | 10 | 380 | banded | 4.75 | — | 6.5–9 |
Mini TT380 slimline | 5 | 380 | banded | 4.75 | 29.5 | >5 |
10 | 380 | banded | 4.75 | 35.8 | 6.5–9 | |
Nova T380 | 5 | 380 | un-banded | 3.6 | 32 | 6.5–9 |
5 | 380 | un-banded |
| 35.4 | 6.5–9 | |
5 | 380 | un-banded |
| 28.4 | >5 | |
Flexi T 300 | 5 | 300 | un-banded | 4.75 | 28 | >5 |
Multiload Cu375 | 5 | 375 | un-banded | 3.6 | 35 | 6–9 |
Multisafe 375 short stem | 5 | 375 | un-banded | 3.85 | 29.4 | 5–7 |
GynaeFix Viz 330 | 5 | 330 | frameless | 4 | 30 | Any |
GynaeFix Viz 200 | 3 | 200 | frameless | 4 | — | Any |
The intrauterine ball is a new frameless Cu-IUD that is not yet licensed for use. Once fitted, it takes on a three dimensional spherical form inside the uterus. A small study following 15 women for 1 year after insertion found no perforations, expulsion, malpositions, complications or pregnancies with this new device.8 Clearly, however, large studies of longer follow-up are needed to determine the safety and effectiveness of this device.
There are currently two LNG-IUS devices available (Table 2). The 52 mg LNG-IUS (Mirena®) is licensed for 5 years for contraceptive use and releases around 20 µg levonogestrel per day which drops to 10 µg per day by 5 years.9 A 13.5 mg LNG-IUS, (known as Jaydess® in Europe and Skyla® in USA) , is licensed for 3 years for contraceptive use (Table 2).10 For the first 24 days the 13.5 mg LNG-IUS releases 14 µg levonogestrel. After 3 years this decreases to 5 µg per day. The 13.5 mg LNG-IUS also differs from the 52 mg LNG-IUS, in that the insertion device for the former is slightly narrower and the frame is shorter (Table 2). The 13.5 mg LNG IUS also has a silver band at the proximal end, which is designed to facilitate visualization using ultrasound and to distinguish it from the 52 mg LNG-IUS.
Table 2. Levonogestrel (LNG) intrauterine systems available (adapted from Faculty of Sexual and Reproductive Health Care. Intrauterine Contraception. http://www.fsrh.org/admin/uploads/CEUGuidanceIntrauterineContraceptionNov07.pdf. 2007.)
Device | Duration of use (years) | Diameter of insertion tube (mm) | Length (mm) |
Mirena® | 5 | 4.40 | 32 |
Jaydess®/ Skyla® | 3 | 3.80 | 28 |
Although the manufacturers have recommended duration of use for Cu-IUD and LNG-IUS, there is some evidence that efficacy of IUC extends beyond these limits.8 A randomized study of the 52 mg LNG-IUS and Copper T380 Ag IUD found that no pregnancies occurred in years 6 and 7 of use.11
MECHANISMS OF ACTION
Both the Cu- IUD and LNG-IUS works primarily by inhibiting fertilisation due to the toxic effect of copper ions on ova and sperm or LNG effects on sperm penetrability and transport.12 Both Cu-IUD and LNG-IUS also prevent implantation; the Cu-IUD exerts a local inflammatory reaction in the endometrium and the LNG induces endometrial atrophy.12 LNG also causes thickening of the cervical mucus which prevents sperm from entering the uterus, although it is not known how quickly such changes are established. With the 52 mg LNG-IUS, serum levels of LNG are detectable but much lower than peak levels observed with other LNG containing contraceptives and most women (80%) will continue to ovulate with the 52 mg LNG-IUS.13
EFFICACY
IUC is extremely effective since it does not rely on user compliance once fitted. IUC also has the benefit of being reversible. At 1 year it is even more effective than female sterilization.14 Overall there is no difference in pregnancy rates between users of the 52 mg LNG-IUS and the IUDs containing >250 mm2 copper.15 Pregnancy rates for Cu-IUDs with copper content >300 mm2 at 1 year are between 0.1% and 1%.14 A large retrospective Finnish study of 52 mg LNG-IUS users reported pregnancy rates of 0.1% at 1 year and 0.5% at 5 years.16 The 13.5 mg LNG -IUS has a compatible reported pregnancy rate of 0.9% at 3 years.17
CLINICAL ASSESSMENT
A history should be taken from women requesting IUC to determine their suitability for the method and the need for further investigations. Additional investigations (e.g. pelvic ultrasound and endometrial sampling) may be indicated in women with abnormal menstrual bleeding patterns prior to insertion of IUC.7 Women at risk of sexually transmitted infections (STI) should ideally be screened for these prior to insertion .7
The World Health Organization system for determining medical eligibility criteria (MEC) for contraceptive use has been adapted for use in the UK by the Faculty of Sexual and Reproductive Healthcare (FSRH) and by the CDC in the USA.18, 19, 20 Using evidence based systematic reviews, conditions are categorized into one of four categories (Table 3). Table 4 summarizes conditions where use of IUC would not be recommended (MEC 4) according to the MEC of the World Health Organization from 2009.18
Table 3 Medical Eligibility Criteria for contraceptive use. Adapted from WHO18
MEC 1 = A condition for which there is no restriction of method MEC 2 = A condition for which the advantages of the method generally outweigh the theoretical or proven risks MEC 3 = A condition for which the theoretical or proven risks of the method generally outweigh the advantages of using the method MEC 4 = A condition that represents an unacceptable health risk if the contraceptive method is used |
Provision of a method to a woman with a category 3 condition, requires careful clinical judgment since use of that method is not recommended unless there is no acceptable alternative.
Table 4 Medical Eligibility Criteria 4 conditions and intrauterine contraceptive (IUC) use, adapted from WHO18
WHO MEC 4 conditions for use of IUC |
Pregnancy Puerperal sepsis Immediate postseptic abortion Gestational trophoblastic disease – persistently elevated human chorionic gondaotropin levels or malignant disease Cervical cancer (initiation) Current breast cancer (LNG-IUS only) Endometrial cancer (initiation) Uterine fibroids with distortion of the cavity Anatomical abnormalities with distortion of the cavity Current pelvic inflammatory disease Current purulent cervicitis or chlamydia or gonorrhea Pelvic tuberculosis |
Healthcare professionals may be reluctant to offer IUC to nulliparous women or adolescents owing to beliefs it will be difficult or carry higher risks.21 However, there is in fact little evidence to support this common misconception and the evidence that does exist is reassuring.22 The World Health Organization (WHO), Faculty of Sexual and Reproductive Healthcare UK and American College of Obstetricians and Gynecologists all support use of IUC in young women and nulliparous women.18, 19, 20
NONCONTRACEPTIVE BENEFITS
Heavy menstrual bleeding
Probably the most notable noncontraceptive benefit of the 52 mg LNG-IUS is that of reducing heavy menstrual blood loss. It is more effective than oral treatments such as norethisterone (a progestogen), the combined oral contraceptive pill, and tranexamic acid (ann antifibrinolytic), at reducing menstrual blood flow and improving quality of life.23 It also appears to be comparable in effectiveness to endometrial ablation but is more cost-effective than both endometrial ablation and hysterectomy at 2 years.23
The 13.5 mg LNG-IUS, is not licensed for use as a treatment for heavy menstrual bleeding. Whilst it does reduce menstrual bleeding and amenorrhea rates improve with time, the amenorrhea rate at 3 years of use was significantly less than that observed with the 52 mg LNG-IUS in a randomized controlled trial (12.7% vs 23.6%).24
Dysmenorrhea
The 52 mg LNG-IUS may also be used to treat primary dysmenorrhea25 and dysmenorrhea associated with endometriosis and adenomyosis.26, 27, 28 There is evidence from a Cochrane review that fitting an 52 mg LNG-IUS at the time of surgery reduces the time between recurrences of painful periods in women with endometriosis.29
It is possible that this may be partly due to an effect of LNG absorbed from the uterus, since a small study of 11 women with rectovaginal endometriosis showed both symptom improvement and reduction in size of endometriotic lesions using ultrasound over 1 year of 52 mg LNG-IUS use.30
Endometrial protection
The 52 mg LNG-IUS affords endometrial protection against the proliferative effects of unopposed estrogen therapy (i.e. as part of hormone replacement therapy) and is licensed for this purpose in the UK.9, 31 Amongst breast cancer patients taking tamoxifen (an antiestrogen), use of the 52 mg LNG-IUS has also been associated with a reduced incidence of endometrial polyps.32 Whilst there is some evidence that it also prevents and causes regression of endometrial hyperplasia, there is still insufficient evidence to support its routine use for the treatment or prevention of endometrial hyperplasia in high risk groups including women using tamoxifen.32
SIDE-EFFECTS AND RISKS
Whether women choose to use the Cu-IUD or LNG-IUS may depend on their perceptions about the benefits, side-effects and risks of the method. Poor counselling may ultimately result in poor uptake or high discontinuation. Higher discontinuation rates will also make IUC less cost-effective. Qualitative research shows that women often lack accurate knowledge about IUC, often rely on information about contraception from friends and family and often hold negative misconceptions about IUC.33 This highlights the need for good information provision about IUC to dispel misconceptions and inform about the benefits of the method.
Bleeding pattern
The most common causes for discontinuation of IUC are pain and menstrual bleeding patterns.34, 35 Although some women will have normal bleeding patterns following insertion of LNG-IUS others will experience longer and more frequent bleeding episodes.36 The cause of this unscheduled bleeding is not fully understood. However, women can be advised that a reduction in menstrual blood loss and an increase in amenorrhea rates can be expected over the first year of use with the 52 mg LNG-IUS.7 Although most women welcome lighter or absent periods37, 38 for others it may be an unwanted side-effect. A large Finnish study found that women who had received quality information about side-effects in advance of their fitting, in particular on absent menstruation, were more satisfied with their IUS at follow-up.39
Spotting, light bleeding, prolonged bleeding and heavy bleeding are common in the first 3–6 months of using the Cu-IUD.40 However, this should settle with time. There is some evidence that addition of a nonsteroidal anti inflammatory drug or antifibrinolytic (tranexamic acid) may reduce menstrual blood loss with the Cu-IUD.41
Hormonal side-effects
Hormonal side-effects associated with the LNG-IUS are likely to decrease with time. Although the manufacturers for the LNG-IUS list acne, breast tenderness, mood disturbance and headaches as common side-effects),9 a systemic review failed to demonstrate any differences in side-effect profile between the 52 mg LNG-IUS and Cu-IUD.42 The side-effect profile of the 13.5 mg LNG-IUS has been reported to be similar to the 52 mg LNG-IUS.24 Effects of hormonal contraception on libido are difficult to study as there several factors that influence libido and robust studies are lacking. Existing evidence fails to show that the LNG-IUS has negative effects on libido. Again a causal relationship between weight and hormonal contraception is difficult to establish. Weight gain has been reported with both Cu-IUD and LNG-IUS, although this does not appear to differ between these methods.43
Ectopic pregnancy
Women using IUC should be informed that their overall risk of ectopic pregnancy is much reduced compared with women who are using no contraception. The risk of ectopic pregnancy for 52 mg LNG-IUS users has been reported as 0.01 per 100 women years (95% CI 0.00–0.003) and 0.07 per 100 women years 95% CI 0.02–1.78) for Cu-IUD users.44 There are relatively few data on the 13.5 mg LNG-IUS. However, the absolute risk of ectopic pregnancy in a phase III trial of the 13.5 mg LNG-IUS was 0.10 per 100 women years (CI 0.02–0.29).17
Although the absolute risk of ectopic is low with IUC use, if a pregnancy does occur with IUC in situ then the ‘relative’ risk of that pregnancy being ectopic is higher. In a multicountry European prospective study (EURAS), approximately 20% of all pregnancies occurring in women with IUC were ectopic pregnancies.44
Perforation
Overall the perforation rates with IUC are low with reported rates of up to two perforations per 1000 insertions.7 Factors associated with an increased risk of perforation have been reported to include relative inexperience of the clinician inserting the IUC,45 breastfeeding and being less than 6 months postpartum,46, 47, 48, 49 fewer pregnancies47 and more abortions.47 Although there is evidence of increased perforation rates in breastfeeding women, breastfeeding is not a contraindication to IUC,18 but the clinician should be alert to signs and symptoms of perforation. There does not appear to be a significant difference in perforation rates between devices. In particular a Cochrane review concluded that there were no significant differences in perforation rates between framed and nonframed Cu-IUDs.50
Expulsion
It is reported that 1 in 20 IUC devices will be expelled and that this is most likely to happen in the first 3 months after insertion.1 In general, similar expulsion rates are reported for both the Cu-IUD and LNG-IUS.7 Retrospective studies have reported that the risk of Cu-IUD expulsion (but not LNG-IUS) is higher amongst nulliparous compared to parous women.51, 52 There is no evidence that expulsion rates differ depending on use of menstrual protection (tampons, pads or menstrual cups).53
Infection
The overall risk of pelvic inflammatory disease (PID) following insertion of IUC is low. A large retrospective cohort study54 found the risk of PID within the first 90 days of fitting was 0.54%. However, PID is more likely immediately following insertion, six fold increased risk in the first 3 weeks, and in women at risk of STIs.7 The UK FSRH guidance suggests screening women at risk of STIs for chlamydia, gonorrhea, HIV and syphilis, and offering prophylactic antibiotics (at to cover chlamydia) to women at high risk of infection if insertion needs to be done before results of tests are known (for example, emergency Cu-IUD fitting).7
INSERTION
Timing
IUC can be fitted at any point in the cycle provided there is no risk of pregnancy. A Cu-IUD will be effective immediately for contraception. It is less clear how long the LNG-IUS takes to become effective. However, the Summary of Product Characteristics, WHO, UK and USA guidance advise that no additional precautions are required if the IUS is fitted on day 1–7 of the cycle and 7 days of additional precautions are recommended if fitted out with this time.7, 18, 19, 20
Postabortion
Observational studies from a number of countries have shown that women who choose an IUC, immediately postabortion have a significantly reduced risk of another abortion in the subsequent year or two compared to counterparts choosing other methods.55 Most women will ovulate within the first month after their abortion and so are at risk of pregnancy again if initiation of effective contraception is delayed.56 WHO recommend that a Cu-IUD or IUS can be inserted immediately after abortion so long as the clinician is sure the woman is no longer pregnant.57
Clinicians can be reassured that fitting IUC immediately postabortion is safe and they should be encouraged to promote this method to women. A large randomized controlled trial (>500 women) from the USA showed that women who had a Cu-IUD fitted immediately after surgical abortion (first trimester) had similar low complication rates compared with women who had delayed insertion (2–6 weeks later).58 In particular, there were no perforations, low rates of pelvic infection (2%) and expulsion rates in both groups were similar (~5%) at 6 months. Continuation rates in the immediate insertion group were higher at 6 months and the only pregnancies that occurred were in the delayed insertion group in women who had failed to return for IUC. The risk of expulsion may be slightly higher if the device is fitted immediately after a late first trimester or mid trimester surgical abortion compared with early first trimester insertion.59
Sometimes it is not possible to fit IUC immediately after early medical abortion, for example if the woman chooses to have the abortion at home. Evidence shows that insertion of IUC within 1 week of early medical abortion (<9 weeks) does not increase the risk of expulsion and perforation compared with delayed insertion (at 3–4 weeks).59, 60 The clinician needs to exclude an ongoing pregnancy. Insertion of the Cu-IUD does not adversely impact upon duration or heaviness of bleeding postabortion, but women who choose a LNG-IUS postmedical or surgical abortion can benefit straight away with reduced bleeding.59, 60 It is also possible that insertion of IUC soon after medical abortion maybe easier than at a later stage, since the cervix may be slightly dilated.
There are no studies looking at immediate insertion of IUC after mid trimester medical abortion. Women who, for whatever reason, are having a delayed insertion of their IUC should be offered a bridging method of contraception to use until insertion of their chosen IUC can take place.
Postpartum
Inserting IUC immediately postpartum compared with delayed insertion is likely to be more convenient and less painful for women. With the constraints and pressures of having a new baby, women may be less likely to attend for IUC at a later date.59 A Cochrane review found there to be no increased risk of perforation or infection when IUC was fitted immediately after delivery (within 10 minutes of placental delivery) compared with women who had interval insertion 6–8 weeks later.61, 62 Expulsion rates in women having immediate insertion have been reported as high as 24–38%62, 63, 64 but this should be weighed up against the benefits of immediate insertion.
Insertion of IUC at the time of cesarean section (placement directly into the cavity before closing the uterus) has also been shown to be safe and convenient for women. Insertion at this time may also be relatively easier for the clinician compared to insertion weeks later through the narrow cervix. In addition, the risk of expulsion appears low when the device is fitted at the time of cesarean section delivery.65
Observational studies have shown that for women choosing a Cu-IUD, the bleeding associated with insertion can be masked by lochia during the puerperium and women choosing the LNG-IUS can benefit from reduced menstrual bleeding in the weeks following childbirth.66
Although there are theoretical concerns about the effects of the low dose of progestogen released into breast milk from the LNG-IUS on the neonate, the available evidence to date regarding all progestogen only methods of contraception and breastfeeding is reassuring. A recent systematic review of studies on progestogen only contraception and breastfeeding mothers showed that the effects on breastfeeding, composition of milk, infant health and growth were consistently reassuring.67
Practical procedure
It is important that clinicians are adequately trained in fitting IUC and maintain this competency. Higher perforation rates are reported amongst clinicians who fit fewer than ten devices over a 6 month period.66 In the UK the Faculty of Sexual and Reproductive Health advise that for recertification of their competency clinicians must therefore fit a minimum of 12 IUCs of at least two different devices over a 12 month period.7 In addition, the FSRH advise that clinicians should attend regular updates in resuscitation so they are equipped to deal with any emergencies that occur during the procedure. A chaperone/assistant should be present for the procedure and informed consent obtained prior to fitting the device. A bimanual pelvic examination should be performed on all women prior to IUC insertion. This allows the clinician to assess the size, position and mobility of the uterus. There is no evidence to suggest that cleansing/washing the cervix prior to insertion prevents infection. If a ‘no touch’ technique (i.e. anything that is inserted into the uterus is held by the handle only) is used for insertion then sterile gloves are not required. Tissue forceps (for example vulsellum) applied to the cervix will stabilize the cervix and straighten the uterine angle. This in turn should make the insertion easier and reduce the risk of perforation. A uterine sound should then be passed to measure the uterocervical length, since knowing this length helps the clinician place the device appropriately at the fundus, and may reduce the risk of perforation.
Ease of insertion and pain relief
Anticipated pain at the time of the procedure may be a barrier to the use of IUC for some women. Nulliparous women and those who have never had a vaginal birth, tend to find the insertion procedure more painful.68 However, women can be advised that approximately half of women report little or no pain.7 A nonrandomized prospective study found that insertions were more difficult in women with shorter uterine lengths and steeper flexion gradient of the uterus.69
A Cochrane review found no differences between the Cu-IUDs studied in terms of ease of insertion or pain at time of insertion.70 However, in a randomized phase II study clinicians reported easier insertion and participants reported less painful insertion when using the narrower and smaller framed 13.5 mg LNG-IUS compared with the 52 mg LNG-IUS.24
There is no good evidence that topical local anesthetic gel improves pain.71 However, paracervical and intracervical administration of local anesthetic has been shown to be associated with lower pain scores and may also be useful if dilation of the cervix is required or if a difficult insertion is anticipated.72, 73 Other interventions that have been studied to ease the pain associated with insertion include bladder filling (to straighten the uterine axis),74 the use of misoprostol (to dilate the cervix)71 and nonsteroidal anti-inflammatory drugs (NSAIDs) (as analgesia) prior to fitting.75 None of these measures have been found to reduce the pain associated with insertion.
MANAGING COMPLICATIONS
Bleeding
When abnormal bleeding patterns occur with IUC pregnancy, STIs and gynecological causes should be considered and excluded. Pelvic examination, pregnancy testing and STI testing should be considered. In addition ultrasound and/or endometrial biopsy (especially in women over the age of 45) should also be considered if abnormal bleeding is persistent or is associated with other features such as pain/dyspareunia.76 If no underlying cause is found, then women can continue with the method if they choose to do so. There is no good evidence to support the use of any additional medications for unscheduled bleeding with the LNG-IUS such as tranexamic acid (antifibrinolytic) or NSAID.76, 77 However, a Cochrane review found that NSAIDs and tranexamic acid may help pain and bleeding associated with the Cu-IUD.41 A woman with heavy periods with the Cu-IUD in situ may also consider changing to the LNG-IUS.
‘Lost’ threads
Most clinicians will advise women to either examine themselves or attend a clinician for an examination to check threads are still present within 6 weeks of insertion of the device. While ‘lost’ threads may indicate pregnancy, expulsion or perforation, it is often the case that the threads are retracted in the cervical canal or uterus.
A pregnancy test should be performed and emergency contraception/alternative contraception provided whilst the patient is waiting for an ultrasound to confirm that the device is in situ in the uterus. If the device is confirmed to be in situ and needs to be removed/replaced, then thread retrievers or forceps can be used by an experienced clinician. Occasionally hysteroscopy may be required to remove the device if threads cannot be retrieved.
Perforation
Uterine perforation can present in a number of ways. Sometimes the clinician will suspect perforation has happened at the time of fitting the device and in this situation the procedure should be abandoned and the woman monitored until stable. Around 30% of women78 will have no symptoms of perforation and the diagnosis will be made due to the detection of lost threads, pregnancy or symptoms. Women may notice mild lower pelvic pain or change in bleeding pattern or give a history of painful insertion.78, 79
If perforation is suspected, the woman should be managed as for ‘lost threads’ as above and if the ultrasound shows no evidence of a device in the uterus, then a plain abdominal X-ray should be performed. If perforation is confirmed (i.e. device visible on X-ray but not seen in the uterus with ultrasound) then the woman should be referred for laparoscopic retrieval. Alternative contraceptive cover should also be provided.
Nonfundal device placement
There is concern that a nonfundally placed IUC may not provide optimal contraceptive cover or may be at higher risk of expulsion. Unfortunately, there is no good evidence to support or refute this concern. The clinician should manage such cases on an individual basis along with the woman's preference.
Pregnancy
In women who become pregnant with IUC in situ, an ultrasound scan should be conducted to exclude ectopic pregnancy. It is generally advisable that IUC should be removed before 12 weeks' gestation in view of the a greater risk of miscarriage, preterm delivery, septic abortion and chorioamnionitis if the device is left in situ.7 Although there is a theoretical concern about teratogenicity if a pregnancy is exposed to the LNG-IUS, to date no birth defects have been reported in the small number of cases exposed.9
Pelvic infection
A systematic review concluded that there were no differences in clinical or laboratory outcomes in IUC users with PID who had their IUC removed compared with women who had their device left in situ.80 The FSRH, UK advise that routine removal of IUC is not necessary in cases of PID but should be considered if there is no response to treatment.7 If the IUC is removed, then the clinician should provide oral emergency contraception if required (i.e. due to recent unprotected sex).
Actinomyces-like organisms
Actimomyces-like organisms (ALOs) in the reproductive tract of women are commonly identified through cervical screening programs in women with and without IUC. The role of ALOs in infection in IUC users is not clear. If a woman with an IUC has ALOs but has no symptoms of infection, then the device can generally be left in situ.7 An IUC can also safely be removed and immediately reinserted in women with ALOs.81 However, if ALOs are present and a woman with an IUC has symptoms of infection then removal of the device and penicillin based antibiotics given.82 In addition, it is advisable to test women with symptoms of pelvic infection for STIs.
RETURN TO FERTILITY
Women may have concerns surrounding the effects of IUC, on their fertility.83 Evidence suggests that the Cu-IUD and the LNG-IUS do not cause a delay in return to fertility or increase the risk of infertility1, 84 and women should be advised of this.
EMERGENCY CONTRACEPTION
The Cu-IUD can also be used as emergency contraception (EC). It is the most effective method of EC available (failure rate 1 in 1000) and should be offered to all eligible women.85 The device can then be used as ongoing contraception or removed once pregnancy has been excluded. Since the blastocyst will implant between 6 and 10 days after fertilization,86 an emergency Cu-IUD should be fitted no more than 5 days after the unprotected sex or 5 days after predicted ovulation in order to avoid disrupting an implanted pregnancy.85 There is no evidence that the LNG-IUS is effective as EC and should therefore not be used for this purpose.
CONCLUSION
IUC is highly effective, safe, well tolerated and cost-effective. However, the importance of counselling women about possible side-effects and risks cannot be underestimated. Clinicians also need to remain up to date with current guidance and regularly fit devices in order to provide their patients with the best standard of care.
IUC can reduce the number of unintended pregnancies for women but unfortunately it remains an unpopular method of contraception in high income countries. More needs to be done to improve the uptake of these methods especially amongst young women at risk of unintended pregnancy. Provision of high quality accurate information to women on IUC, that dispels myths and provides information on benefits is important.33, 87 In addition, emphasis should be placed on removing the cost barrier55 of these methods and ensuring that providers are up to date with recommendations for use of IUC and are trained and funded to provide these methods to women.
REFERENCES
National Institute for Health and Clinical Excellence (NICE). Long-acting reversible contraception: the effective and appropriate use of long-acting reversible contraception. 2005. http://www.nice.org.uk/pdf/CG030fullguideline.pdf [Accessed 05 October 2014]. |
|
Trussell, J, Glob. libr. women's med.,(ISSN: 1756-2228) 2014; DOI 10.3843/GLOWM.10375 (access date 7 November 2014) |
|
d'Arcangues C: Worldwide use of intrauterine devices for contraception. Contraception. 2007 Jun;75(6 Suppl):S2-7. Epub 2007 Apr 19 |
|
Lader D. Contraception and sexual health 2008/9. A report on research using the ONS Omnibus survey produced by the office for National Statistics, 2009 available at www.statistics.gov.uk (access date 7 November 2014) |
|
Michie L, Cameron ST. Improving the uptake of long acting reversible contraception: a review. Minerv Ginecol 2013;65241-52. |
|
Kulier, R., Helmerhorst, F. M., O'Brien, P., Usher-Patel, M., and d'Arcangues, C. Copper containing, framed intra-uterine devices for contraception (Review). Cochrane Database of Systematic Reviews 2007;(4). |
|
Faculty of Sexual and Reproductive Health Care. Intrauterine Contraception. http://www.fsrh.org/admin/uploads/CEUGuidanceIntrauterineContraceptionNov07.pdf. 2007.[Last accessed 13 October 2014] |
|
Baram I, Weinstein A, Trussell J. The IUB, a newly invented IUD: a brief report. Contraception 2014; 89(2):139-41 |
|
Bayer plc. Mirena: Summary of Product Characteristics. http://www.medicines.org.uk/. 2013. |
|
Bayer plc. Jaydess 13.5mg intrauterine delivery system: summary of product characteristics. London: Bayer plc.; 2014. |
|
Sivin, I., Stern, J., Coutinho, E., Mattos, C. E., el Mahgoub, S., Diaz, S., Pavez, M., Alvarez, F., Brache, V., and Thevenin, F. Prolonged intrauterine contraception: a seven-year randomized study of the levonorgestrel 20mcg/day (LNg 20) and the Copper T380 Ag IUDS. Contraception 1990; 44(5):473-480. |
|
Ortiz ME, Croxatto HB.Copper T intrauterine device and olevonorgestrel intrauterine system: biological bases of their mechanism of action. Contraception 2007;75:S42-S51. |
|
Ratsula K, Toivonen J, Lahteenmaki P, Luukkainen T. Plasma levonogestrel levels and ovarian function during the use of a levonogestrel- releasing intracervical contraceptive device. Contraception. 1989 Feb;39(2):195-201 |
|
World Health Organization: Improving Access to Quality Care in Family Planning: Medical Eligibility Criteria for Contraceptive Use. 2nd ed. Geneva, WHO, 2004 |
|
French, Rebecca, Sorhaindo, Annik M., Van-Vliet-Huib, A. A. M., Mansour, Diana D., Robinson, A. A., Logan, Stuart, Helmerhorst, Frans M., Guillebaud, John, and Cowan, Frances M. Progestogen-releasing intrauterine systems versus other forms of reversible contraceptives for contraception. Cochrane Database Syst Rev 2004. |
|
Backman T, Rauramo I, Huhtala S, Koskenvuo M. Pregnancy during the use of levonorgestrel intrauterine system. Am J Obstet Gynecol. 2004;190:50–54 |
|
Nelson, A., Apter, D., Hauck, B., Schmelter, T., Rybowski, S., Rosen, K., and Gemzell-Danielsson, K. Two low-dose levonorgestrel intrauterine contraceptive systems: a randomized controlled trial. Obstet.Gynecol. 2013; 122(6):1205-1213. |
|
World Health Organization. Medical Eligibility Criteria for Contraceptive Use 4th Edition 2009. [4th Edition], http://www.who.int/reproductivehealth/publications/family_planning/9789241563888/en/index.html. 2010. |
|
United States Medical Eligibility Criteria (USMEC) for Contraceptive www.cdc.gov/reproductivehealth/unintendedpregnancy/usmec.htm |
|
Faculty of Sexual and Reproductive Health Care. UK Medical Eligibility Criteria for Contraceptive Use. (UKMEC 2009). http://www.fsrh.org/admin/uploads/UKMEC2009.pdf. 2009 |
|
Black, K., Lotke, P., Buhling, K. J., and Zite, N. B. A review of barriers and myths preventing the more widespread use of intrauterine contraception in nulliparous women. European Journal of Contraception and Reproductive Health Care 2012; 17(5):October. |
|
Deans, E. I. and Grimes, D. A. Intrauterine devices for adolescents: a systematic review. [Review] [43 refs]. Contraception 2009; 79(6):418-423 |
|
Lethaby, A. E., Cooke, I., and Rees, M. Progesterone or progestogen-releasing intrauterine systems for heavy menstrual bleeding (Review). The Cochrane Library 2005;(3):CD002126. DOI: 10.1002/14651858.CD002126.pub2 |
|
Gemzell-Danielsson, K., Schellschmidt, I., and Apter, D. A randomized, phase II study describing the efficacy, bleeding profile, and safety of two low-dose levonorgestrel-releasing intrauterine contraceptive systems and Mirena. Fertil.Steril. 2012; 97(3):616-622 |
|
Lindh, I. and Milsom, I. The influence of intrauterine contraception on the prevalence and severity of dysmenorrhea: a longitudinal population study. Human Reproduction 2013; 28(7):1953-1960. |
|
Bayoglu, Tekin Y., Dilbaz, B., Altinbas, S. K., and Dilbaz, S. Postoperative medical treatment of chronic pelvic pain related to severe endometriosis: levonorgestrel-releasing intrauterine system versus gonadotropin-releasing hormone analogue. Fertil.Steril. 2011; 95(2):492-496 |
|
Lockhat, F. B., Emembolu, J. O., and Konje, J. C. The efficacy, side-effects and continuation rates in women with symptomatic endometriosis undergoing treatment with an intra-uterine administered progestogen (levonorgestrel): a 3 year follow-up. Human Reproduction 2005; 20(3):789-793 |
|
Ozdegirmenci O., Kayikcioglu F, Akgul MA, Kaplan M, Karcaaltincaba M, Haberal A, and Akyol M. Comparison of levonorgestrel intrauterine system versus hysterectomy on efficacy and quality of life in patients with adenomyosis. Fertil Steril 2011; 95(2):497-502 |
|
Abou-Setta, A. M., Houston, B., Al-Inany, H. G., and Farquhar, C. Levonorgestrel-releasing intrauterine device (LNG-IUD) for symptomatic endometriosis following surgery. Cochrane Database of Systematic Reviews 2013; 1:CD005072. DOI: 10.1002/14651858.CD005072.pub3. |
|
Fedele l, Bainchi S, Zanconato G, Portugese A, Rafffaelli R. Use of a levonorgesterl releasing intrauterine device in the treatment of rectovaginal endometriosis. Fertil Steril 2001;75:485-488 |
|
Wan, Y. L. and Holland, C. The efficacy of levonorgestrel intrauterine systems for endometrial protection: a systematic review. [Review]. Climacteric 2011; 14(6):622-632 |
|
Wong AW1, Chan SS, Yeo W, Yu MY, Tam WH Prophylactic use of levonorgestrel-releasing intrauterine system in women with breast cancer treated with tamoxifen: a randomized controlled trial.Obstet Gynecol. 2013 May;121(5):943-50. |
|
Michie L, Cameron ST, Glasier A, et al. Myths and misconceptions about intrauterine contraception among women seeking termination of pregnancy. J Fam Plann Reprod Health Care 2014;40:36-40 |
|
Grunloh, D. S., Casner, T., Secura, G. M., Peipert, J. F., and Madden, T. Characteristics associated with discontinuation of long-acting reversible contraception within the first 6 months of use. Obstet.Gynecol. 2013; 122(6):1214-1221. |
|
Jenabi, E., Alizade, S. M., and Baga, R. I. Continuation rates and reasons for discontinuing TCu380A IUD use in Tabriz, Iran. Contraception 2006; 74(6):483-486. |
|
36. Datey, S, Gaur, L N, and Saxena, B N. Vaginal Bleeding Patterns of Women Using Different Contraceptive Methods (Implants, Injectables, IUDs, Oral Pills) An Indian Experience. Contraception 1995; 51:155-165. |
|
den Tonkelaar I, Oddens BJ. Preferred frequency and characteristics of menstrual bleeding in relation to reproductive status, oral contraceptive use, and hormone replacement therapy use. Contraception 1999;59:357–62 |
|
Backman T, Huhtala S, Blom T, et al. Length of use and symptoms associated with premature removal of the levonorgestrel intrauterine system: a nation-wide study of 17,360 users. BJOG 2000;107:335–9 |
|
Backman T, Huhtala S, Luoto R, Tuominen J, Rauramo I, Koskenvuo M. Advance information improves user satisfaction with the levonorgestrel intrauterine system. Obstet Gynecol. 2002;99:608–13. |
|
World Health Organization. Selected Practice Recommendations for Contraceptive Use (2nd edn). 2005. http://www.who.int/reproductive-health/publications/spr_2/ index.html [Accessed 12 October 2014]. |
|
Grimes D, Hubacher D, Lopez LM, and Schulz KM. Non-steroidal anti-inflammatory drugs for heavy bleeding or pain associated with intrauterine-device use. Cochrane Database of Systematic Review 2006;(4) |
|
French, R. S., Cowan, F. M., Mansour, D. J. A., Morris, S., Procter, T., Hughes, D., Robinson, A., and Guillebaud, J. Implantable contraceptives (subdermal implants and hormonally impregnated intrauterine systems) versus other forms of reversible contraceptives: two systematic reviews to assess relative effectiveness, acceptability, tolerability and cost-effectiveness. Health Technology Assessment 2000; 4(7). |
|
Dal'Ava, N., Bahamondes, L., Bahamondes, M. V., de Oliveira, Santos A., and Monteiro, I. Body weight and composition in users of levonorgestrel-releasing intrauterine system. Contraception 2012; 86(4):350-353. |
|
Heinemann K, Reed S, and Moehner S. Ectopic Pregnancies under IUD use: Interim results from the EURAS-IUD study. Pharmacoepidemiology and Drug Safety 2013; 22(1):430. |
|
Harrison-Woolrych, M, Ashton, Janelle, and Coulter, David. Uterine perforation on intrauterine device insertion: is the incidence higher than previously reported? Contraception 2003; 67:53-56. |
|
Kaislasuo, J., Suhonen, S., Gissler, M., Lahteenmaki, P., and Heikinheimo, O. Intrauterine contraception: incidence and factors associated with uterine perforation--a population-based study. Human Reproduction 2012; 27(9):2658-2663. |
|
Caliskan, E., Öztürk, N., Dilbaz, B. Ö., and Dilbaz, S. Analysis of risk factors associated with uterine perforation by intrauterine devices. Eur J Contraception Reprod Health Care 2003; 8(150):155. |
|
Andersson, K., Ryde-Blomqvist, E., Lindell, K., Odlind, V., and Milsom, I. Perforations with intrauterine devices: Report from a Swedish survey. Contraception 1998; 57:251-255. |
|
van Grootheest K., Sachs, B., Harrison-Woolrych, M., Caduff-Janosa, P., and van, Puijenbroek E. Uterine perforation with the levonorgestrel-releasing intrauterine device: analysis of reports from four national pharmacovigilance centres. Drug Safety 1-1-2011; 34(1):83-88. |
|
O'Brien, P. A. and Marfleet, C. Frameless versus classical intrauterine device for contraception. Cochrane Database of Systematic Reviews 2005;(1):CD003282. DOI: 10.1002/14651858.CD003282.pub2. |
|
Behringer T, Reeves MF, Rossiter B, Chen BA, Schwarz EB. Duration of use of a levonorgestrel IUS amongst nulliparous and adolescent women. Contraception. 2011 Nov;84(5):e5-e10. |
|
Garbers S, Haines-Stephan J, Lipton Y, Meserve A, Spieler L, Chiasson MA. Continuation of copper-containing intrauterine devices at 6 months. Contraception. 2013 Jan;87(1):101-6 |
|
Wiebe ER, Trouton KJ. Does using tampons or menstrual cups increase early IUD expulsion rates? Contraception. 2012 Aug;86(2):119-21. |
|
Sufrin, C. B., Postlethwaite, D., Armstrong, M. A., Merchant, M., Wendt, J. M., and Steinauer, J. E. Neisseria gonorrhea and Chlamydia trachomatis screening at intrauterine device insertion and pelvic inflammatory disease. Obstetrics & Gynecology 2012; 120(6):1314-1321. |
|
Peipert JF, Madden T, Allsworth JE, Secura GM. Preventing unintended pregnancies by providing no-cost contraception. Obstet Gynaecol 2012;120(6):1291-7 |
|
Schreiber CA, Sober S, Ratcliffe S, et al. Ovulation resumption after medical abortion with mifepristone and misoprostol. Contraception 2011;84:230-3 |
|
Schreiber CA, Sober S, Ratcliffe S, et al. Ovulation resumption after medical abortion with mifepristone and misoprostol. Contraception 2011;84:230-3 |
|
Bednarek PH, Creinin MD, Reeves MF, et al. Post Aspiration IUD Randomization (PAIR) study trial group. Immediate verus delayed IUD insertion after uterine aspiration. N Engl J Med 2011;364:2208-17 |
|
Cameron S. Postabortal and postpartum contraception Best Pract Res Clin Obstet Gynaecol. 2014;28(6):871-80 |
|
Grimes DA, Lopez LM, Schulz KF, Van Vilet HAAM, and Stanwood NL. Immediate post-partum insertion of intrauterine devices. Cochrane 61.. Database of Systematic Review 2010;(5):Art. No.: CD003036. DOI: 10.1002/14651858.CD003036.pub2. |
|
Database of Systematic Review 2010;(5):Art. No.: CD003036. DOI: 10.1002/14651858.CD003036.pub2. |
|
Kapp, N. and Curtis, K. M. Intrauterine device insertion during the postpartum period: a systematic review. [Review] [18 refs]. Contraception 2009; 80(4):327-336. |
|
Stuart GS, Bryant AG, O’Neill E, et al. Feasibility of postpartum placement of the levonogestrel intrauterine system more than 6h after vaginal birth. Contraception 2012;85:359-62 |
|
Chen BA, Reeves MF, Hayes JL, et al. Postplacental or delayed insertion of the levonogestrel intrauterine device after vaginal delivery: a randomized controlled trial. Obstet Gynaecol 2010;116:1079-87 |
|
Levi E, Cantillo E, Ades V, et al. Immediate postplacental IUD insertion at cesarean delivery: a prospective cohort study. Contraception 2012; 86:102-5 |
|
Harrison-Woolrych, M, Zhou, L, and Coulter D. Insertion of intrauterine devices: A comparison of experience with Mirena and multiload Cu 375 during post-marketing monitoring in New Zealand. New Zealand Medical Journal 2003; 116(1179):pp7. |
|
Kapp N, Curtis K, Nanda K Progestogen-only contraceptive use among breastfeeding women: a systematic review. Contraception. 2010;82(1):17-37 |
|
Allen, R. H., Carey, M. S., Raker, C., Goyal, V., and Matteson, K. A prospective cohort study of pain with intrauterine device insertion among women with and without vaginal deliveries. J.Obstet.Gynaecol. 2014; 34(3):263-267. |
|
Kaislasuo, J., Heikinheimo, O., Lahteenmaki, P., and Suhonen, S. Predicting painful or difficult intrauterine device insertion in nulligravid women. Obstet.Gynecol. 2014; 124(2 Pt 1):345-353. |
|
Kulier, R., Helmerhorst, F. M., O'Brien, P., Usher-Patel, M., and d'Arcangues, C. Copper containing, framed intra-uterine devices for contraception (Review). Cochrane Database of Systematic Reviews 2007;(4). |
|
Allen RH, Bartz D, Grimes DA, Hubacher D, and O'Brien P. Interventions for pain with intrauterine device insertion. Cochrane Database of Systematic Review 2009;(3) |
|
Mody SK, Kiley J, Rademaker A, Gawron L, Stika C, and Hammond C. Pain control for intrauterine device insetion: a randomized trial of 1% lidocaine paracervical block. Contraception 2012 |
|
Cirik, DA, Taskin, EA, Tuglu, A, Ortac, AS, and Dai, O. Paracervical block with 1% lidocaine for pain control during intrauterine device insertion: a prospective, single-blinded, controlled study. International Journal of Reproduction, Contraception, Obstetrics and Gynecology 2013; 2(3):263-267. |
|
Cameron, S. T., Glasier, A., Cooper, A., and Johnstone, A. Does a full bladder assist insertion of intrauterine contraception? A randomised trial. Journal of Family Planning & Reproductive Health Care 2013; 39(3):207-210. |
|
Hubacher, D., Reyes, V., Lillo, S., Zepeda, A., Chen, P., and Croxatto, H. Pain from copper intrauterine device insertion: Randomized trial of prophylactic ibuprofen. American Journal of Obstetrics and Gynecology 2006; 195:1272-1277. |
|
Faculty of Sexual and Reproductive Health Care. The management of unscheduled bleeding in women using hormonal contraception. 2009. |
|
Warner, P., Guttinger, A., Glasier, A. F., Lee, R. J., Nickerson, S., Brenner, R. M., and Critchley, H. O. Randomized placebo-controlled trial of CDB-2914 in new users of a levonorgestrel-releasing intrauterine system shows only short-lived amelioration of unscheduled bleeding. Human Reproduction 2010; 25(2):345-353 |
|
Kaislasuo, J., Suhonen, S., Gissler, M., Lahteenmaki, P., and Heikinheimo, O. Uterine perforation caused by intrauterine devices: Clinical course and treatment. Human Reproduction 2013; 28(6):1546-1551. |
|
79. Andersson, K, Ryde-Blomqvist, E, Lindell, K, Odlind, V, and Milsom, I. Perforations With Intrauterine Devices. Contraception 1998; 57:251-255. |
|
Tepper, N. K., Steenland, M. W., Gaffield, M. E., Marchbanks, P. A., and Curtis, K. M. Retention of intrauterine devices in women who acquire pelvic inflammatory disease: a systematic review. [Review]. Contraception 2013; 87(5):655-660. |
|
Burkman, R. T. Intrauterine Devices and Pelvic Inflammatory Disease: Evolving Perspectives on the Data. Obstetrics & Gynecological Survey 1996; 51(12):S35-S41 |
|
Fiorino, A. S. Intrauterine contraceptive device-associated actinomycotic abscess and Actinomyces detection on cervical smear. Obstetrics & Gynaecology 1996; 87(1):142-149. |
|
Glasier A., Scorer, J., and Bigrigg, A. Attitudes of women in Scotland to contraception: a qualitative study to explore the acceptability of long-acting methods. Journal of Family Planning and Reproductive Health Care 2008; 34(4):213-217. |
|
Hov, G. G., Skjeldestad, F. E., and Hilstad, T. Use of IUD and subsequent fertility--follow-up after participation in a randomized clinical trial. Contraception 2007; 75(2):88-92. |
|
Faculty of Sexual and Reproductive Health. Emergency Contraception. 2012 |
|
Wilcox AJ, Baird DD, Weinberg CR. Time of implantation of the conceptus and loss of pregnancy. N Engl J Med 1999; 340: 1796–1799. |
|
Arrowsmith ME, Aicken CR, Saxena S, et al. Strategies for improving the acceptability and acceptance of the copper intrauterine device. Cochrane Database Syst Rev 2012;3:1469493X |